Complications requiring reoperation following vaginal mesh kit procedures for prolapse

Published:October 10, 2008DOI:https://doi.org/10.1016/j.ajog.2008.07.049

      Objective

      The objective of the study was to the characterize the symptoms and management of vaginal mesh-related complications requiring operative intervention.

      Study Design

      This was a case series of patients undergoing excision of vaginal graft material. Only women who had vaginal mesh placement for the correction of pelvic organ prolapse (POP) were included. We describe the symptoms, complications, and management of women treated surgically for vaginal mesh-related complications.

      Results

      Thirteen referred women underwent surgery for vaginal mesh-related complications. All meshes were Apogee and/or Perigee. Ten had symptomatic mesh exposures, 1 had an exposure with pelvic abscess, and 2 had pain syndromes without mesh exposure. Patients also had rectovaginal fistula, vesicovaginal fistula, recurrent POP, and persistent discharge. Five women had prior surgery for this problem. All patients underwent transvaginal mesh excision and other indicated procedures at our institution, and 6 women required a second surgery at our institution, with a median of 2 surgeries per patient.

      Conclusion

      Vaginal mesh placement for POP can be associated with pain, exposure, and fistula formation, requiring multiple operative interventions.

      Key words

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to American Journal of Obstetrics & Gynecology
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Nygaard I.E.
        • McCreery R.
        • Brubaker L.
        • et al.
        Abdominal sacrocolpopexy: a comprehensive review.
        Obstet Gynecol. 2004; 104: 805-823
        • Visco A.G.
        • Weidner A.C.
        • Barber M.D.
        • et al.
        Vaginal mesh erosion after abdominal sacral colpopexy.
        Am J Obstet Gynecol. 2001; 184: 297-302
        • Cosson M.
        • Debodinance P.
        • Boukerrou M.
        • et al.
        Mechanical properties of synthetic implants used in the repair of prolapse and urinary incontinence in women: which is the ideal material?.
        Int Urogynecol J Pelvic Floor Dysfunct. 2003; 14 (78; discussion 178): 169
        • Deffieux X.
        • de Tayrac R.
        • Huel C.
        • et al.
        Vaginal mesh erosion after transvaginal repair of cystocele using gynemesh or gynemesh-soft in 138 women: a comparative study.
        Int Urogynecol J Pelvic Floor Dysfunct. 2007; 18: 73-79
        • Gauruder-Burmester A.
        • Koutouzidou P.
        • Rohne J.
        • Gronewold M.
        • Tunn R.
        Follow-up after polypropylene mesh repair of anterior and posterior compartments in patients with recurrent prolapse.
        Int Urogynecol J Pelvic Floor Dysfunct. 2007; 18: 1059-1064
        • Fatton B.
        • Amblard J.
        • Debodinance P.
        • Cosson M.
        • Jacquetin B.
        Transvaginal repair of genital prolapse: preliminary results of a new tension-free vaginal mesh (prolift technique)—a case series multicentric study.
        Int Urogynecol J Pelvic Floor Dysfunct. 2007; 18: 743-752
        • Hiltunen R.
        • Nieminen K.
        • Takala T.
        • et al.
        Low-weight polypropylene mesh for anterior vaginal wall prolapse: a randomized controlled trial.
        Obstet Gynecol. 2007; 110: 455-462
        • Collinet P.
        • Belot F.
        • Debodinance P.
        • Ha Duc E.
        • Lucot J.P.
        • Cosson M.
        Transvaginal mesh technique for pelvic organ prolapse repair: mesh exposure management and risk factors.
        Int Urogynecol J Pelvic Floor Dysfunct. 2006; 17: 315-320
        • Tamussino K.F.
        • Hanzal E.
        • Kolle D.
        • Ralph G.
        • Riss P.A.
        • Austrian Urogynecology Working Group
        • Austrian Urogynecology Working Group
        Tension-free vaginal tape operation: results of the Austrian registry.
        Obstet Gynecol. 2001; 98: 732-736
        • Tamussino K.
        • Hanzal E.
        • Kolle D.
        • et al.
        Transobturator tapes for stress urinary incontinence: results of the austrian registry.
        Am J Obstet Gynecol. 2007; 197: 634.e1-634.e5
        • Baessler K.
        • Hewson A.D.
        • Tunn R.
        • Schuessler B.
        • Maher C.F.
        Severe mesh complications following intravaginal slingplasty.
        Obstet Gynecol. 2005; 106: 713-716